Multipara Monitor
Multipara Monitor
Product Code : STAR 5000H-i
Product Description

MULTIPARA MONITOR


ln-hospital application include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas

  • Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable

  • Can be used to monitor adult, pediatric & neonate patient

  • Low perfusion working possible

  • Various display screen : Trend Coexist Display, OxyCRG Dynamic View Display, Bed to Bed view Display

  • Arrhythmia Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S-T segment analysis, pacemaker detection Drug calculation and titration table

  • Networking capacity and nurse call system

  • Large volume of tabular and graphic trends information storage and easy to recall

  • Capture dynamic waveforms

  • In-built Rechargeable battery which provides a backup time of upto 4 hours

  • User friendly menu structure with easy to use rotary dial

  • Protection Against electrosurgical interference and defibrillation

  • Intelligent audio and visual comprehensive alarm. Volume adjustment possible

Standard Configuration : ECG, HR, Sp02, ST Analysis, Resp, NIBP, 2* Temp, Drug Dose Calculator, built in battery 
Optional Configuration :
 Recorder, 2*IBP, EtC02 (Main Stream or Side Stream)

TECHNICAL SPECIFICATIONS 

ECG 
Lead Mode : 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
 
Lead selection: I, II, III, avR, avL, avF, V,
 
Waveform : 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL) Lead selection : I, II, III, Waveform : 1 ch
 
Gain: 2.5mm/mV, 5.0mm/mV, lOmm/mV, 20mm/mV, auto
 
HR Alarm Range
 
Adult: 15 ~ 300 bpm
 
Neo/Ped : 15 ~ 350 bpm
 
Accuracy : ± 1% or ± 1 bpm,which great
 
Resolution : 1 bpm
 
Bandwidth
 
Surgery : 1 ~ 15 Hz
 
Monitor : 0.5 ~ 35 Hz
 
Diagnostic : 0.05 ~ 100 Hz
 
ST Segment Monitoring Range : Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting
Type : ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
 



RESPIRATION 
Method : R-F(RA-LL) Impedance
 
Resp. Rate Measuring and Alarm Range
 
Adult : 0 ~ 1 20 rpm
 
Neo/Ped : 0 ~ 150 rpm
 
Resolution : 1 rpm
 
Accuracy : ±2 rpm
 
Apnea Alarm : 10 ~ 40s
 

NIBP
 
Method: Oscillometric
 
Mode: Manual, Auto, STAT
 
Pulse Rate Range: 40 ~ 240 bpm
 
Alarm Type : SYS, DIA, MEAN
 
Measuring and alarm range
 
Adult Mode
 
SYS: 40 ~ 270 mmHg
 
DIA: 10 ~ 215 mmHg
 
MEAN: 20 ~ 235 mmHg
 
Pediatric Mode
 
SYS: 40 ~ 200 mmHg
 
DIA: 10 ~ 150 mmHg
 
MEAN: 20 ~ 165 mmHg
 
Neonatal Mode
 
SYS: 40 ~ 135 mmHg
 
DIA: 10 ~ 100 mmHg
 
MEAN: 20 ~ 1 10 mmHg
 
Resolution Pressure: lmmHg
 
Accuracy Pressure Maximum Mean error : ±5 mmHg

Overpressure Protection
 
Adult Mode: 297±3 mmHg
 
Pediatric Mode: 240±3 mHg
 
Neonatal Mode: 147±3 mmHg


Sp02
Measuring Range : 0 ~ 100 % Alarm Range : 0 ~ 100 % Resolution : 1 % 
Accuracy : 70% ~ 100% ±2 %
 
0% ~ 69% unspecified
 

Pulse Rate
 
Measuring and Alarm Range: 20~300bpm
 
Resolution: 1 bpm
 
Accuracy: ±2bpm
 

Temperature
 
Channel: 2
 
Measuring and Alarm Range: 0 ~ 50°C
 
Resolution: 0.1 °C
 
Accuracy: ±0.1 °C
 

IBP 
Label: ART, PA, CVP, RAP, LAP, ICP, PI, P2
 
Measuring and alarm range
 
ART: 0 ~ 300 mmHg
 
PA: -6 ~ 1 20 mmHg
 
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
 
P1/P2: -10 ~ 300 mmHg
 
Press Sensor Sensitivity: 5uV/V/mmHg Impedance: 300-3000Q
 
Resolution: 1 mmHg
 
Accuracy: ±2% or ± 1 mmHg, which is greater
 
Actualization interval : about Is
 
Dimension: 320 x 160 x 270mm
 
Net Weight : <5kg
 
Gross Weight : <8kg



Martand Medical Services

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.